radicalolz.blogg.se

Windows storage server 2008 r2 standard iso
Windows storage server 2008 r2 standard iso









windows storage server 2008 r2 standard iso

Or by running the Windows PowerShell cmdlets from the Pure Storage PowerShell SDK. If the deployed switches in the fabric support changing the Maximum Transmission Unit (MTU) from 1500 to 9000 (Jumbo Frames) this can be accomplished using the FlashArray Management GUI. The Host Port Connectivity should show Redundant connections. Open up the FlashArray Management interface, click System tab, click Connections, click Host Connections and select host that was just configured. After completing the setup of the Initiator IPs and Target Portal IPs click the Favorite Targets tab and all of the configured paths will be visible.ġ1.

windows storage server 2008 r2 standard iso

Repeat Step 9 for all of the Initiator IPs and map to their appropriate Target portal IP.ġ0. Select the Target portal IP from the dropdown that will map to the Initiator IP. Select the appropriate IP Address from the Initiator IP dropdown. In the Advanced Settings dialog select the Microsoft iSCSI Initiator from the Local adapter dropdown. Click Enable multi-path then click Advanced. button.ĩ. The Connect To Target dialog will apperar.

windows storage server 2008 r2 standard iso

Select the Connected Discovered targets and click Connect.Ĩ. This is the same FlashArray iSCSI Qualified Name (IQN) that can be seen from the FlashArray management interface.ħ. If a FlashArray volume has not been connected to the host where the iSCSI Initiator Service is being setup you will see the error, Authorization Failure.

  • Now the new host, Server01, is connected to the new volume, iSCSI-TestVolume, with the host port IQN set to :server01.
  • Click on the iSCSI-TestVolume (or whatever volume name was created) then click Confirm.
  • The Connect Volumes to Host dialog will open.
  • After creating the new volume click the Connected Volume (0) tab then the 'hamburger menu' to the right and select Connect Volumes menu item.
  • For this example the name iSCSI-TestVolume with a size of 500 G is being used.
  • Click on the + in the Volumes section to create a volume.
  • Enter the IQN from the previous section then click Add.
  • The Configure iSCSI IQNs dialog box will open.
  • Select the newly created host, Server01, then click the Host Ports tab. Click the 'hamburger menu' to the right, then click Configure iSCSI IQNs.
  • Click on the + in the Hosts section and select Create Host.
  • Open the Pure Storage FlashArray Management interface and log into the FlashArray.
  • Connecting a volume to a configured iSCSI host on the Pure Storage FlashArray is required before configuring MSiSCSI.











    Windows storage server 2008 r2 standard iso